金磁微粒模拟酶比色检测谷胱甘肽的研究

关桦楠, 吴巧艳, 陈彦宇, 薛悦, 彭勃

现代化工 ›› 2022, Vol. 42 ›› Issue (1) : 242 -247.

PDF (1629KB)
现代化工 ›› 2022, Vol. 42 ›› Issue (1) : 242-247. DOI: 10.16606/j.cnki.issn0253-4320.2022.01.049
分析测试

金磁微粒模拟酶比色检测谷胱甘肽的研究

    关桦楠, 吴巧艳, 陈彦宇, 薛悦, 彭勃
作者信息 +

Detection of glutathione using Fe3O4@Au nanocomposite with peroxidase mimicking activity

Author information +
文章历史 +
PDF (1667K)

摘要

通过自组装法制备磁性纳米复合材料金磁微粒(Fe3O4@Au),对其进行表征,并优化Fe3O4@Au模拟酶检测谷胱甘肽的体系,确定检测限、回收率和抗干扰性。研究结果表明,最佳催化体系为:H2O2浓度50 mmol/L,催化温度60℃,反应时间为4 min。谷胱甘肽浓度在0.01~0.5 mmol/L时,吸光度差值与浓度呈现良好的线性关系,线性方程y=1.157 5x+0.272 8,线性相关系数R2为0.990 7,最低检测限度为0.3 μmol/L,样品回收率分别为91.92%和110.31%,选择性良好。

Abstract

Fe3O4@Au nanocomposite is prepared by self-assembling method and characterized.Fe3O4@Au mimetic enzyme system for detecting glutathione is optimized to determine the detection limit,recovery and anti-interference.The optimum detection conditions are obtained as follows:H2O2 concentration is 50 mmol·L-1,catalytic temperature is at 60℃,and reaction time is 4 min.Under the optimized conditions,a good linear relationship is shown between the absorbance difference and the concentration of glutathione in the range of 0.01-0.5 mmol·L-1,and the equation is y=1.157 5x+0.272 8 (R2=0.990 7).The lowest detection limit is 0.3 μmol·L-1.The recoveries ranges from 91.92% and 110.31%.

关键词

金磁微粒 / 食品分析 / 谷胱甘肽 / 模拟酶

Key words

Fe3O4@Au nanocomposite / food analysis / glutathione / mimetic enzyme