利用共沉淀法制备Cu-Mn-Ce/海泡石催化剂,利用XRD、TEM和BET等表征其物化性质,进一步构建非均相催化臭氧氧化体系。探讨了不同实验条件下布洛芬废水的去除效率。得到的最优反应条件为:Cu-Mn-Ce负载量为20%、臭氧通量为30 mg/min、催化剂添加质量为0.45 g、pH=7,此时,布洛芬废水TOC的去除率可达96.17%。循环实验表明,催化剂重复利用5次后,降解效率仍为93.28%,表明催化剂重复利用性能良好。

Abstract

Coprecipitation method is employed to prepare Cu-Mn-Ce/sepiolite catalyst with sepiolite as carrier.XRD,TEM and BET characterization are carried out to explore the physicochemical properties of the catalyst.On this basis,a heterogeneous catalytic ozonation system is constructed to treat with ibuprofen wastewater.The removal effect of ibuprofen wastewater by the catalyst is explored under different single-factor conditions.The optimum reaction conditions are gained as follows:the load of Cu-Mn-Ce is 20%,the mass flow of ozone is 30 mg·min-1,the dosage of the catalyst is 0.45 g,and initial solution pH=7.Under these optimum conditions,the removal rate of TOC in ibuprofen wastewater can reach 96.17%.The catalytic degradation efficiency of Cu-Mn-Ce/sepiolite can still reach 93.28% after five cycles,indicating a good reusability.

关键词

Cu-Mn-Ce/海泡石 / 布洛芬废水 / 降解 / 催化臭氧氧化 / 非均相

Key words

Cu-Mn-Ce/sepiolite / ibuprofen wastewater / degradation / catalytic ozonation / heterogeneous

Author summay

王洪华(1973-),女,硕士,高级工程师,研究方向为水污染研究与控制,18098337@qq.com

引用本文

引用格式 ▾
Cu-Mn-Ce/海泡石的制备及其催化臭氧氧化布洛芬废水性能研究[J]. 现代化工, 2020, 40(11): 136-138,143 DOI:10.16606/j.cnki.issn0253-4320.2020.11.028

登录浏览全文

4963

注册一个新账户 忘记密码

参考文献

AI Summary AI Mindmap
PDF (2208KB)

213

访问

0

被引

导航
相关文章

AI思维导图

/