In combination with the specific situation of a certain refinery,the combustion trials of different VOCs simulation gas are performed in an FCC pilot regenerator.The results show that NMHC concentration in regenerated flue gas can reach in the range of 1-41 mg/m3 after combustion of different kinds of high concentration VOCs simulation gas in an FCC pilot regenerator under the conditions that meet working conditions of commercial FCC unit,which can meet local VOCs emission concentration standard of no more than 70 mg/m3.