有机线粒体内HClO/ClO-荧光探针研究进展
杨志广, 洪晓云, 田丰收, 李艳霞, 王筠
周口师范学院化学化工学院, 河南 周口 466001
Research progress in fluorescent probes for HClO/ClO- within organic mitochondria
YANG Zhi-guang, HONG Xiao-yun, TIAN Feng-shou, LI Yan-xia, WANG Jun
School of Chemistry and Chemical Engineering, Zhoukou Normal University, Zhoukou 466001, China
下载:  PDF (1612KB) 
输出:  BibTeX | EndNote (RIS)      
摘要 基于荧光探针与线粒体内HClO/ClO-的识别机理,介绍了近年来有机单、双光子线粒体内HClO/ClO-荧光探针的研究现状,并对其未来发展方向进行了展望。
服务
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章
杨志广
洪晓云
田丰收
李艳霞
王筠
关键词:  线粒体  次氯酸/次氯酸根  荧光探针  双光子  生物成像    
Abstract: Based on the recognition mechanism of fluorescent probes for HClO/ClO- within mitochondria,the research status of fluorescent probes for HClO/ClO- within organic single photon and double photon mitochondria is reviewed and the future development direction is prospected.
Key words:  mitochondria    hypochlorous acid/hypochlorite root    fluorescent probe    two-photon    bio-imaging
收稿日期:  2018-04-16      修回日期:  2018-09-07          
O657.3  
基金资助: 周口师范学院校本项目(ZKNUB1201804);河南省科技厅科技攻关计划项目(172102310626);河南省高等学校重点科研项目计划(18B430019)
通讯作者:  杨志广(1980-),男,博士,讲师,研究方向为有机功能材料,通讯联系人,yangzhiguang2006420@126.com。    E-mail:  yangzhiguang2006420@126.com
引用本文:    
杨志广, 洪晓云, 田丰收, 李艳霞, 王筠. 有机线粒体内HClO/ClO-荧光探针研究进展[J]. 现代化工, 2018, 38(11): 58-61.
YANG Zhi-guang, HONG Xiao-yun, TIAN Feng-shou, LI Yan-xia, WANG Jun. Research progress in fluorescent probes for HClO/ClO- within organic mitochondria. Modern Chemical Industry, 2018, 38(11): 58-61.
链接本文:  
http://www.xdhg.com.cn/CN/10.16606/j.cnki.issn0253-4320.2018.11.013  或          http://www.xdhg.com.cn/CN/Y2018/V38/I11/58
[1] McBride H M,Neuspiel M,Wasiak S.Mitochondria:More than just a powerhouse[J].Current Biology,2006,16(14):R551-R560.
[2] Ferretta A,Gaballo A,Tanzarella P,et al.Effect of resveratrol on mitochondrial function:Implications in parkin-associated familiar Parkinson's disease[J].Biochimica et Biophysica Acta,2014,1842(7):902-915.
[3] Wisnovsky S,Lei E K,Jean S R,et al.Mitochondrial chemical biology:New probes elucidate the secrets of the powerhouse of the cell[J].Cell Chemical Biology,2016,23(8):917-927.
[4] Nogueira V,Hay N.Reactive oxygen species homeostasis in cancer cells and implications for cancer therapy[J].Clinical Cancer Research,2013,19(16):4309-4314.
[5] Kang J,Huo F J,Yue Y K,et al.A solvent depend on ratiometric fluorescent probe for hypochlorous acid and its application in living cells[J].Dyes and Pigments,2017,136:852-858.
[6] Yang Y,Qiu F Z,Wang Y Z,et al.A sensitive and selective off-on fluorescent probe for HClO in 100% aqueous solution and its applications in bioimaging[J].Sensors and Actuators B:Chemical,2018,260:832-840.
[7] Yao S,Belfield K D.Two-photon fuorescent probes for bioimaging[J].European Journal of Organic Chmistry,2012,2012(17):3199-3217.
[8] Lim C S,Cho B R.Two-photon probes for biomedical imaging[J].Tetrahedron,2015,71(43):8219-8249.
[9] Qu Z J,Ding J X,Zhao M Y,et al.Development of a selenide-based fluorescent probe for imaging hypochlorous acid in lysosomes[J].Journal of Photochemistry and Photobiology A:Chemistry,2015,299:1-8.
[10] 李海东,樊江莉,彭孝军.识别次氯酸的荧光探针[J].化学进展,2017,29(1):17-35.
[11] Zhang Y R,Liu Y,Feng X,et al.Recent progress in the development of fluorescent probes for the detection of hypochlorous acid[J].Sensors and Actuators B:Chemical,2017,240:18-36.
[12] Shen S L,Zhang X F,Ge Y Q,et al.A novel ratiometric fluorescent probe for the detection of HOCl based on FRET strategy[J].Sensors and Actuators B:Chemical,2018,254:736-741.
[13] 姜娜,樊江莉,杨洪宝,等.线粒体荧光探针最新研究进展[J].化工学报,2016,67(1):176-190.
[14] Ross M F,Prime T A,Abakumova I,et al.Rapid and extensive uptake and activation of hydrophobic triphenylphosphonium cations within cells[J].Biochemical Journal,2008,411(3):633-645.
[15] Xi L L,Guo X F,Wang C L,et al.A near-infrared ratiometric fluorescent probe for rapid and selective detection of hypochlorous acid in aqueous solution and living cells[J].Sensors and Actuators B:Chemical,2018,255:666-671.
[16] Deng B B,Ren M G,Kong X Q,et al.Development of an enhanced turn-on fluorescent HOCl probe with a large Stokes shift and its use for imaging HOCl in cells and zebrafish[J].Sensors and Actuators B:Chemical,2018,255:963-969.
[17] Cao J J,Jiang D M,Ren X,et al.A highly selective two-photon probe with large turn-on signal for imaging endogenous HOCl in living cells[J].Dyes and Pigments,2017,146:279-286.
[18] Cheng G H,Fan J L,Sun W,et al.A highly specific BODIPY-based probe localized in mitochondria for HClO imaging[J].Analyst,2013,138(20):6091-6096.
[19] Xiao H D,Li J H,Zhao J,et al.A colorimetric and ratiometric fluorescent probe for ClO- targeting in mitochondria and its application in vivo[J].Journal of Materials Chemistry B,2015,3(8):1633-1638.
[20] Tian F S,Jia Y,Zhang Y N,et al.A HClO-specific near-infrared fluorescent probe for determination of myeloperoxidase activity and imaging mitochondrial HClO in living cells[J].Biosensors and Bioelectronics,2016,86:68-74.
[21] Li G,Ji D D,Zhang S M,et al.A mitochondria-targeting fluorescence turn-on probe for hypochlorite and its applications for in vivo imaging[J].Sensors and Actuators B:Chemical,2017,252:127-133.
[22] Lv J,Chen Y H,Wang F,et al.A mitochondria-targeted fluorescent probe based on fluorescein derivative for detection of hypochlorite in living cells[J].Dyes and Pigments,2018,148:353-358.
[23] Hu Q,Qin C Q,Huang L,et al.Selective visualization of hypochlorite and its fluctuation in cancer cells by a mitochondria-targeting ratiometric fluorescent probe[J].Dyes and Pigments,2018,149:253-260.
[24] Yuan L,Wang L,Agrawalla B K,et al.Development of targetable two-photon fluorescent probes to image hypochlorous acid in mitochondria and lysosome in live Cell and inflamed mouse model[J].Journal of the American Chemical Society,2015,137(18):5930-5938.
[25] Xu Q L,Heo C H,Kim J A,et al.A selective imidazoline-2-thione-bearing two-photon fluorescent probe for hypochlorous acid in mitochondria[J].Analytical Chemistry,2016,88(12):6615-6620.
[26] Shen B X,Qian Y,Qi Z Q,et al.Near-infrared BODIPY two-photon ClO- probe based on thiosemicarbazide desulfurization reaction:Naked-eye detection and mitochondria imaging[J].Journal of Materials Chemistry B,2017,5(29):5854-5861.
[27] Feng Y,Li S Q,Li D X,et al.Rational design of a diaminomaleonitrile-based mitochondria-targeted two-photon fluorescent probe for hypochlorite in vivo:Solvent-independent and high selectivity over Cu2+[J].Sensors and Actuators B:Chemical,2018,254:282-290.
[28] Li G Y,Lin Q,Sun L L,et al.A mitochondrial targeted two-photon iridium(Ⅲ) phosphorescent probe for selective detection of hypochlorite in live cells and in vivo[J].Biomaterials,2015,53:285-295.
[1] 李雪梅, 付大友, 袁东, 郭雪琰, 周睿璐. 量子点荧光探针在分析检测中的应用研究[J]. 现代化工, 2017, 37(6): 205-208.
[2] 韩蕾, 李小慧, 杨晶晶, 张艺, 居尔艾特提拜克·吾加, 刘云庆. 硅烷化ZnS量子点用于Cd2+检测[J]. 现代化工, 2017, 37(11): 210-212.
[3] 刘珊珊, 左桂福, 韩大庆, 孙海娜, 宗培肖. 石墨氮化碳在荧光探针中的应用研究进展[J]. 现代化工, 2017, 37(11): 202-205,207.
[4] 杨玲, 廖超强, 曹杰, 张学俊. 合成新型荧光增强型探针用于巯基蛋白质的检测[J]. 现代化工, 2016, 36(3): 178-181,183.
[5] 姜诚, 陶圣燃, 陈群, 沐逸冰, 张乐琦, 王玮. 荧光探针测定乙交酯中总质子浓度[J]. 现代化工, 2015, 35(8): 177-179.
[6] 张琤琦, 张淑娟, 曹立伟, 吕晓猛. 分子荧光探针在含能材料废水检测中的应用[J]. 现代化工, 2014, 34(11): 163-167.
[7] 范丛斌,章洛汗,蒲守智,王筱梅. 双光子诱导有机光致变色材料的研究进展[J]. , 2009, 29(10): 0-0.